edilint / rule reference

edifact / error

EL7008

edifact.nesting

Applies to: edifact

What it catches and why it matters

UNG or UNH appears outside the envelope that must enclose it, or no UNB is present in a file forced to the edifact format.

Failing example

These synthetic fragments illustrate the defect; they are not complete interchange files. Backslash escapes name bytes such as \r (CR) and \n (LF).

UNH+1+INVOIC:D:96A:UN'UNT+2+1'  (no enclosing UNB)

How to fix it

Place messages and groups inside the required interchange envelope, or lint the complete interchange instead of a standalone fragment.

False positives and limits

Forcing --type edifact on another format, or checking only an extracted message, can trigger missing-envelope findings. Confirm the input scope and format.

Acknowledgments and suppression

No direct acknowledgment code is mapped for this rule.
CONTRL references use syntax-error element 0085, not action element 0083. UCI, UCF and UCM report interchange, group and message service-segment errors respectively. A missing or unreadable header can prevent a valid CONTRL response. Truncation, orphaned envelopes and data outside an interchange have no single mapping here.
Sources: https://service.gefeg.com/jwg1/Archive/v3/mt/m01.htm https://service.gefeg.com/jwg1/Archive/cl/v3/21a/cl16.htm
Suppress the rule with --disable EL7008, or list it under "disable" in .edilint.yml. To accept the occurrences a file already has without suppressing the rule, record them with --write-baseline and run with --baseline.
Reference: https://crb2nu.github.io/edilint/rules/EL7008.html

All rules · Configuration